Paradox Magellan Systems 17
24Hr. Gas Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 012
When a 24Hr. Gas zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm.
The SIA FSK reporting format includes specific report codes
to identify the alarm as a Gas alarm.
24Hr. Heat Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 013
When a 24Hr. Heat zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm.
The SIA FSK reporting format includes specific report codes
to identify the alarm as a Heat alarm.
24Hr. Water Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 014
When a 24Hr. Water zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm.
The SIA FSK reporting format includes specific report codes
to identify the alarm as a Water alarm.
24Hr. Freeze Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 015
When a 24Hr. Freeze zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm.
The SIA FSK reporting format includes specific report codes
to identify the alarm as a Freeze alarm.
Zone Options
Sections [001] to [016] represent zones 1 through 16
respectively as demonstrated in Figure 14 on page 15. After
entering the 3-digit Zone Definition (see Zone Definitions on
page 15), select one or more of the following Zone Options by
using the Feature Select Programming Method (see page 13):
Auto-zone Shutdown
Sections [001] to [016]: Zones 1 to 16; Option [1]
Option [1] OFF = Auto-zone Shutdown disabled
Option [1] ON = Auto-zone Shutdown enabled (default)
If, in a single armed period, the number of alarms generated
by a zone with the Auto Zone Shutdown option enabled
exceeds the number defined by the Auto Zone Shutdown
Counter, the console will no longer generate an alarm for
that zone. The Auto Zone Shutdown Counter resets every
time the system is armed.
Auto-zone Shutdown Counter
Section [067]: 001 to 015 alarms; 000 = Disabled;
Default = 5 alarms
Enter the desired limit into section [067] to program the
Auto-zone Shutdown Counter.
Bypass Option
Section [001] to [016]: Zones 1 to 16; Option [2]
Option [2] OFF = Bypass option disabled
Option [2] ON = Selected zone is bypass enabled (default)
When a user uses the Bypass Programming feature, only
zones with the Bypass option enabled can be programmed
as bypassed.
Fire zones cannot be programmed with the Bypass
option because the console will not bypass a Fire
zone.
Alarm Types
Sections [001] to [016]: Zones 1 to 16; Options [4] and [5]
When an alarm condition occurs, the console can be
programmed to react as shown in Table 2 on page 17.
Table 2: Alarm Type Options
The Alarm Type options cannot be programmed for
Fire zones. Fire zones are automatically programmed
with an audible pulsed alarm. This cannot be altered.
Intellizone
Sections [001] to [016]: Zones 1 to 16; option [6]
Option [6] OFF = Intellizone disabled (default)
Option [6] ON = Intellizone enabled
This feature reduces the possibility of false alarms. When a
zone with the Intellizone option opens, the console does not
immediately generate an alarm. First it triggers the
Intellizone Delay Timer. If any of the following conditions
occur during this period, the panel will generate an alarm:
During the Intellizone Delay, a second zone has caused
an alarm.
During the Intellizone Delay, the zone in alarm has
restored (closed) and re-occurred (opened).
The zone in alarm is still open after the Intellizone Delay
has elapsed.
Options Description
[4] [5]
OFF OFF Audible steady alarm (default)
When the conditions for an alarm have been
met, the control panel can transmit the
appropriate Zone Alarm report code (see
page 26) and provides a steady output for the
on-board siren.
OFF ON Audible pulsed alarm
When the conditions for an alarm have been
met, Magellan can transmit the appropriate Zone
Alarm report code (see page 26) and provides a
pulsed output (see Figure 15 on page 16) for the
on-board siren.
ON OFF Silent alarm
When the conditions for an alarm are met, the
control panel can transmit the appropriate Zone
Alarm report code (see page 26) and will not
activate the control panel’s bell output. The
appropriate
ARM or STATUS LED on the keypads
will flash to indicate an alarm and the user will
still have to disarm the system.
ON ON Report only
When the conditions for an alarm have been
met, the control panel can transmit the
appropriate Zone Alarm report code (see
page 26). The system will not have to be
disarmed.