16 Reference & Installation Manual
will prevent the motion detector from causing an alarm when
a user enters through the entry point to disarm the system.
Follow/Stay Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 004
Follow/Stay zones function as follows:
• All zones defined as Follow/Stay zones become Follow
zones (refer to Follow Zones on page 15) when the
Magellan system is Regular armed.
• All zones defined as Follow/Stay zones become Stay
zones when the Magellan system is Stay or Instant
armed.
Instant Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 005
When an armed Instant zone opens, the console
immediately generates an alarm. Instant zones are
commonly used for windows, patio doors, skylights and
other perimeter type zones.
Instant/Stay Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 006
Instant/Stay zones function as follows:
• All zones defined as Instant/Stay zones become Instant
zones (refer to Instant Zones on page 16) when the
Magellan system is Regular armed.
• All zones defined as Instant/Stay zones become Stay
zones when the Magellan system is Stay or Instant
armed.
Standard 24Hr. Fire Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 007
Whenever a Standard 24Hr. Fire Zone opens, whether it is
armed or disarmed, the console will generate the following:
• The console can send the corresponding Alarm Report
Code from sections [187] to [190].
• Alarms are always audible regardless of other settings.
Fire alarms generate an intermittent (pulsed) bell/siren
output signal as shown in Figure 15 on page 16.
Figure 15: Bell/Siren Output during a Fire Alarm
Delayed Fire Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 008
When a Delayed 24Hr. Fire Zone opens, whether it is armed
or disarmed, the console will react as shown in Figure 16 on
page 16. Delayed 24Hr. Fire Zones are commonly used in
residential homes where a smoke detector often generates
false alarms (i.e. burning bread, etc.).
Figure 16: Delayed Fire Zone
24Hr. Burglary Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 009
Whenever a 24Hr. Burglary Zone opens, whether the
system is armed or disarmed, the console will immediately
generate an alarm.
24Hr. Hold-up Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 010
When a 24Hr. Hold-up zone opens, whether it is armed or
disarmed, the console will immediately generate an alarm.
The SIA FSK reporting format includes specific report codes
to identify the alarm as a Hold-up alarm.
24Hr. Buzzer Zones
Sections [001] to [016]: Zones 1 to 16, 3-digit # = 011
This zone definition is particularly useful when a user wishes
to be notified when something such as a safe or locker
within the home has been accessed (i.e. a child accessing a
valuable collection). This zone definition functions as
follows:
• Whenever a 24Hr. Buzzer Zone opens, whether the
console is armed or disarmed, the console sets off the
keypads’ buzzers to indicate that the zone was
breached.
• The console will report the alarm, but will not enable the
bell/siren output.
• Enter any valid access code on the keypad to stop the
buzzer.