All-In-One Wireless Security System V1.0Model #: MG-6060Reference and Installation Manual

Strany 2

8 Reference & Installation ManualHardwire Zone ConnectionsMagellan comes with two on-board hardwire zones. You can connect hardwire detection dev

Strany 3 - Table of Contents

Paradox Magellan Systems 9X10 Transmitter ConnectionMagellan supports the X10 communication protocol. X10 is a communication protocol for remote con

Strany 4

10 Reference & Installation ManualFigure 12: Mounting Magellan onto the Wall PlateFigure 13: Magellan’s Back PlateMounting Magellan on the WallMa

Strany 5 - Introduction

Paradox Magellan Systems 11Programming MethodsWinLoad Installer Upload/Download SoftwareProgram the Magellan console remotely or on-site using the W

Strany 6 - Quick Setup

12 Reference & Installation ManualUser CodesA person must be assigned to a User code in order to have access to Magellan. A User code defines the

Strany 7 - 7.Time and Date

Paradox Magellan Systems 13Zone ProgrammingMagellan supports up to 16 wireless zones whereby each zone can be configured with a different zone defin

Strany 8 - Installation

14 Reference & Installation ManualFollow/Stay ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 004Follow/Stay zones function as follows:•

Strany 9 - Programmable Outputs (PGMs)

Paradox Magellan Systems 1524Hr. Gas ZonesSections [001] to [016]: Zones 1 to 16, 3-digit # = 012When a 24Hr. Gas zone opens, whether it is armed or

Strany 10 - Connection

16 Reference & Installation Manual• During the Intellizone Delay, a second zone has caused an alarm.• During the Intellizone Delay, the zone in a

Strany 11 - Location and Mounting

Paradox Magellan Systems 17Wireless ProgrammingThe Magellan system supports up to 16 wireless zones and two wireless doorbells. These wireless zones

Strany 13 - Programming Methods

18 Reference & Installation Manual• “Weak”: This is the weakest reading. The transmitter should be moved to another location. Sometimes moving th

Strany 14 - User Codes

Paradox Magellan Systems 19Table 5: MG-REM2 Remote Control Button Programming[172] 12______ ______ ______ ______012[173] 13______ ______ ______ ____

Strany 15 - Zone Programming

20 Reference & Installation ManualFigure 19: Remote Control Button Options* = Hex values A to F are keys [1] to [6] from Magellan’s Center Keypad

Strany 16

Paradox Magellan Systems 21Arming and DisarmingRegular Arming Switches to Stay ArmingSection [092]: Option [4]Option [4] OFF = Regular arming switch

Strany 17 - Zone Options

22 Reference & Installation ManualOne-Touch ArmingSection [092]: Options [7] and [8]Option [7] OFF = One-touch Regular/Force arming disabledOptio

Strany 18 - EOL (End-Of-Line) Zones

Paradox Magellan Systems 23Alarm OptionsBell Cut-off TimerSection [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutesAfter an audible ala

Strany 19 - Wireless Programming

24 Reference & Installation ManualTable 7: Tamper Recognition OptionsTamper Bypass OptionsSection [094]: Option [5]Option [5] OFF = Ignore any ta

Strany 20 - Assigning Remote Controls

Paradox Magellan Systems 25Reporting and Dialer SettingsReport CodesA report code is a 1- or 2-digit hexadecimal value consisting of digits from 1 t

Strany 21

26 Reference & Installation Manual• Fire Panic: Panic keys [7] and [9] (see page 24) or the appropriate button(s) on a remote control (see page 1

Strany 22

Paradox Magellan Systems 27Monitoring Station Telephone Numbers (MSTNs)Section [111] = Monitoring Station Telephone Number 1Section [112] = Monitori

Strany 23 - Arming and Disarming

Paradox Magellan Systems 1Table of ContentsIntroduction... 3About Magellan and this Manual...

Strany 24

28 Reference & Installation Manual4. Press [NEXT] until the desired telephone number appears, then press [OK].5. Enter the desired telephone numb

Strany 25 - Alarm Options

Paradox Magellan Systems 29Section [102]: Options [1] to [3]; SpecialOption [1] ON = Call MSTN 1Option [2] ON = Call MSTN 2Option [3] ON = Call Page

Strany 26 - Panic Alarms

30 Reference & Installation ManualTable 11: Telephone Line Monitoring OptionsPlease note that when the dialer detects an incoming call, the TLM t

Strany 27 - Reporting and Dialer Settings

Paradox Magellan Systems 31Programmable OutputsA PGM is a programmable output that toggles to its opposite state (i.e. a normally open PGM will clos

Strany 28 - Console Telephone Numbers

32 Reference & Installation ManualSystem SettingsSoftware ResetSection [201]Performing a software reset will reset all programmed sections back t

Strany 29 - Utility Reporting

Paradox Magellan Systems 33* When a communication failure trouble is acknowledged by pressing [OK], you will be given the option to call your servic

Strany 30 - Event Call Direction

34 Reference & Installation ManualWinLoad Software SettingsPanel Answer OptionsThe following two options define how Magellan answers an incoming

Strany 31 - Paradox Magellan Systems 29

Paradox Magellan Systems 35Appendix 1: Automatic Report Code ListSystem Event Default Contact ID Report Codewhen using sections [790] to [795]Defaul

Strany 32 - TLM Fail Timer

36 Reference & Installation ManualAC Failure 1 3A1 - AC loss AT - AC TroubleBattery Failure 1 3A9 - Battery test failure YT - System Battery Trou

Strany 33 - Programmable Outputs

Paradox Magellan Systems 37Appendix 2: Ademco Contact ID Report Code ListCID# Reporting Code Programming ValueMedical Alarms - 100100 Medical alarm

Strany 34 - System Settings

2 Reference & Installation ManualWinLoad Software Settings ... 34Panel Answer Options ...

Strany 35

38 Reference & Installation ManualCID# Reporting Code Programming Value335 Local printer paper out 54336 Local printer failure 55337 Expansion mo

Strany 36 - WinLoad Software Settings

Paradox Magellan Systems 39CID# Reporting Code Programming Value525 Reversing relay disabled AE526 Notification appliance chk. #3 disabled AF527 Not

Strany 37

40 Reference & Installation ManualIndexNumerics001 to 016 ...13–16021 to 036 ...

Strany 38

Paradox Magellan Systems 41Arming optionsAuto-arm options ...21Bell Squawk on Arm/Disarm with Re

Strany 39

42 Reference & Installation ManualEEntry Delay 1 ...13Entry Delay 2 ...

Strany 40

Paradox Magellan Systems 43Special disarming ...25System trouble ...

Strany 41

44 Reference & Installation ManualSystem master code ...12User code length ...

Strany 42

Paradox Magellan Systems 45

Strany 43 - Paradox Magellan Systems 41

46 Reference & Installation ManualWARRANTYParadox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and

Strany 45 - Paradox Magellan Systems 43

Paradox Magellan Systems 3IntroductionAbout Magellan and this ManualMagellan is designed for fast and easy installation. Simply remove it from the bo

Strany 46

780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADATel.: (450) 491-7444 Fax: (450) 491-7313www.paradox.caPrinted in Canada - 11/2004 MAGELLAN

Strany 47 - Paradox Magellan Systems 45

4 Reference & Installation ManualQuick SetupFollow these steps to quickly set up Magellan with the required settings for a basic security install

Strany 48 - FCC WARNINGS

Paradox Magellan Systems 5When you are done the next menu option will appear. Press [NEXT] until you see the “Passwords” menu or press the [8] key t

Strany 49

6 Reference & Installation ManualInstallationAC PowerMagellan requires a 9Vac (1A) or 16.5Vac (1A) transformer (not included) to supply power to

Strany 50

Paradox Magellan Systems 7For UL compliant installations, the Magellan console must be able to seize the telephone line and place a call in an emerg